Function

Input PAD (−16 dB) control, low cut (cutoff frequency: 100 Hz) control,

analog output attenuator (−6 dB, −12 dB, −18 dB, −24 dB, −36 dB, −42 dB) control,

system lock function, stereo summing function, Control knobs (3 rotary encoders)

Front Panel Section

Input Level Indicator

3-point LED, 12 channels (each monaural input channel, stereo 1L, 1R, 2L, 2R)

Output Level Indicator

8-point LED, 4 channels (each output channel)

Auto Resonance Control

(ARC) Measurement

ARC switch x 1, ARC operation indicator x 1

Feedback Suppressor

(FBS) Function

Feedback Suppressor switch x 8, Feedback suppressor indicator x 8

Low Cut Filter

Low cut switch x 8, Low cut indicator x 8

Summing Output

Monaural summing switch x 2, Monaural summing indicator x 2

Tone Control

BASS, MID, TREBLE/Settable with control knobs, 10 channels

(each monaural input channel, stereo 1L, 1R, 2L, 2R)

Monaural Input, Analog

Setting

Gain setting, PAD ON/OFF, Phantom power ON/OFF

Settable with control knobs, 8 channels (each monaural input channel)

Stereo Input, Analog

Setting

Trim setting

Settable with control knobs, 6 channels (1-A, 1-B, 1-C), (2-A, 2-B, 2-C)

REC OUT, Gain Setting

Gain setting

Settable with control knobs, 2 channels (REC OUT L, REC OUT R)

Preset Memory Switching Preset memory key x 4, Preset memory indicator x 4

System Lock

System lock key x 1, System lock indicator x 1

Operation Status Indication Operation status indicator x 3

Function Setting Section Control knob x 3, 10-point position indication LED x 3, Tone control mode

indicator x 1, Gain control mode indicator x 1, Trim control mode indicator x 1

Analog Volume Fader

Input volume fader x 10, Output volume fader x 4,

2 faders linkable with supplied gang bar

Control Section

Contact Input

8 channels, open voltage: 24 V DC, short-circuit current: 5 mA,

removable terminal block (10 P)

Contact output

8 channels, no-voltage make contact, contact capacity: 24 V DC/100 mA,

removable terminal block (10 P)

Remote Control Panel

2 channels, Maximum number of units: 8 units per channel

24 V DC input x 2, termination switch x 1, removable terminal block (10 P)

Maximum total cable length (star wiring): 800 m or 870 yd (total for 2 channels)

Maximum cable length (daisy chain wiring): 400 m or 435 yd per channel

Note: In daisy chain wiring, the number of units differs depending on the cable length.

Star wiring and daisy chain wiring cannot be used together.

Type of cable: Shielded CPEV cable (a pair of data cable and a pair of power supply

cable) or shielded Cat 5 twisted pair cable for LAN (CAT5-STP)

Network

Network I/F: 1 channel of 10BASE-T/100BASE-TX (auto-negotiation)

RJ45 connector, connection via switching hub

Network protocol: TCP/IP

Connection cable: Shielded Cat. 5 or higher twisted pair cable for LAN

(Cat. 5-STP or better)

Maximum cable length: 100 m or 110 yd (between M-864D and switching hub)

Operating Temperature

0 to 40 ºC (32 to 104 ºF)

Operating Humidity

90 %RH (no condensation)

Finish

Panel: Aluminum, hairline, black, Case: Surface-treated steel plate

Dimensions

482.6 (w) x 177.1 (h) x 157.2 (d) mm (19” x 6.97” x 6.19”)

Weight

5.1 kg (11.24 lb)