beautypg.com

Toa M-864D User Manual

Page 51

background image

51

25.3.1. Cable length for wiring

Cable length and the number of the connectable ZM Remote controllers differ depending on the wiring method.
[Star wiring]
This is a method to directly connect each ZM Remote controller to the M-864D.

Perform wiring installation so that the total cable length between the M-864D and each ZM Remote controller

does not exceed 800 m (870 yd).

Example: Up to 16 ZM Remote controllers can be connected if the total cable length between the M-864D and

each ZM Remote controller is within 800 m (870 yd).

Perform wiring installation so that the total cable length between the M-864D and each ZM Remote

controller does not exceed 800 m (870 yd).

LINK A LINK B

LINK A

or

LINK B

LINK A LINK B

LINK A

LINK B

ZM Remote

controller (1)

(8)

Connection terminal

Connection terminal

ZM Remote controller

M-864D

(9)

(16)

(When connecting a single ZM Remote controller)

(When connecting 16 ZM Remote controllers)

Allowable total cable length of

wiring is 800 m (870 yd).

Maximum 800 m (870 yd)

M-864D

This manual is related to the following products: