beautypg.com

Toa M-864D User Manual

Page 46

background image

46

25.1.3. ZM-9013 Remote Control Panel

The ZM-9013 performs various controls with the 8 buttons in connection to the M-864D.

Communication is executed between the M-864D and ZM-9013, and the indicator status changes depending

on the M-864D’s operation.

It can be mounted in two-gang electrical box.

[Front]

[Side]

1 2

3

1 2

4

5

4

5

1. Function buttons

Press this button to activate the function assigned

to this button.

Following functions can be assigned:

• Channel On/Off

• EXT VOL. Gain

• ST Line Source Select

• Matrix Crosspoint Assign

• Matrix Crosspoint Gain

• Preset Memory Load

• Remote Switched Out

• Remote Command

Function assignment is performed by the PC with

the supplied M-864D PC Software installed. For

details, read the separate Software instructions.

2. Operation indicators

Light if the assigned function is enabled when the

Function button is pressed.

3. Address selector [ADDRESS]

Used to set the ZM-9013’s address (0 – F).

Set the address value not overlapping with the

value assigned to other ZM Remote controller.

The address number ranges from 0 to 9, and A to

F in numerical and alphabetical order.

4. Data line connection terminals

[LINK A, LINK B]

Connect the communication line from the M-864D.

The communication line has polarities. Match the

polarities of data line connection terminals to those

of the D-864D’s data line connection terminals. As

2 sets of these terminals are internally connected

in parallel, either can be used to connect to other

ZM Remote controller.

5. 24 V DC terminals

Connect the power cable from the M-864D.

This manual is related to the following products: