23. INSTALLATION

23.1. Installation Precautions

Be sure to leave the installation work (rack mounting) to a

qualified installer.

(When rack mounting screws are supplied)

The supplied rack-mounting screws can be used for the TOA

equipment rack only. Do not use them for other racks.

When installing the unit in a rack other than that of TOA, be sure to

use the screws with a diameter of over 5 mm (0.2”) and length of over

12 mm (0.47”) to mount the unit.

Failure to do so may cause the unit to fall, resulting in personal injury.

(When rack mounting screws are not supplied)

Rack mounting screws are not supplied with the unit.

Be sure to use the screws with a diameter of over 5 mm (0.2”) and

length of over 12 mm (0.47”) to mount the unit.

Failure to do so may cause the unit to fall, resulting in personal injury.

CAUTION

When installing the unit in an equipment rack, do not

block the ventilation slots on the unit’s both sides and

rear side. Doing so may cause heat to build up inside

the unit and result in fire.

CAUTION

23.2. Rack Mounting

• Elevated Operating Ambient - If installed in a closed or multi-unit rack

assembly, the operating ambient temperature of the rack environment

may be greater than room ambient. Therefore, consideration should be

given to installing the equipment in an environment compatible with the

maximum ambient temperature (Tma) specified by the manufacturer.

• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required

for safe operation of the equipment is not compromised.

• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

• Circuit Overloading - Consideration should be given to the connection of the equipment to the supply

circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.

Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

• Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention

should be given to supply connections other than direct connections to the branch circuit (e.g. use of power

strips)."

DIGIT

AL S

TER

EO M

IXER

M-86

4D

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

1

1

10

9
8
7
6
5
4
3
2

2

10

9
8
7
6
5
4
3
2

3

10

9
8
7
6
5
4
3
2

4

10

9
8
7
6
5
4
3
2

5

10

9
8
7
6
5
4
3
2

6

10

9
8
7
6
5
4
3
2

I

N

P

U

T

O U

T P

U

T

7

10

9
8
7
6
5
4
3
2

8

10

9
8
7
6
5
4
3
2

ST

1

10

9
8
7
6
5
4
3
2

ST

2

10

9
8
7
6
5
4
3
2

1

10

9
8
7
6
5
4
3
2

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1

2

3

4

1/ST

2

3

4

1/ST

2

3

4

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK

0dB
-40dB
LOW

CUT

FBS
TONE

/GAIN

ASSIG

N

PEAK
+12
+6

-6
-12
-24
-40

dB

0

2

10

9
8
7
6
5
4
3
2

PEAK
+12
+6

-6
-12
-24
-40

dB

0

3

10

9
8
7
6
5
4
3
2

PEAK
+12
+6

-6
-12
-24
-40

dB

0

4

10

9
8
7
6
5
4
3
2

PEAK
+12
+6

-6
-12
-24
-40

dB

0

PEAK

0dB
-40dB

MONO

TONE

/TRIM

ASSIG

N

L

R

PEAK

0dB
-40dB

MONO

TONE

/TRIM

ASSIG

N

L

R

ST2

INPU

T

ARC

REC O

UT

BASS

GAIN

VOL

MID

PAD

VOL

REB

LE

RUN
LOCK

REMO

TE

LOC

AL

ON

POWE

R

OFF

PHAN

TOM

VOL

3

4

2 PR

ESET

1

Power amplifier

Rack

M-864D

Blank panel

• Température ambiante élevée - si l’appareil est installé dans un bâti fermé ou en même temps que d’autres

appareils, la température à l’intérieur risque de devenir supérieure à la température ambiante. Par conséquent,

veiller à installer l’équipement dans un environnement compatible à la température ambiante maximum

spécifiée par le fabricant.

• Débit d’air réduit - L’installation de l’équipement en bâti ne doit pas compromettre le débit d’air nécessaire à

une utilisation sûre de l’équipement.

• Charge mécanique - Le montage de l’équipement en bâti ne doit pas entraîner de danger dы а une surcharge

mécanique inégale.

• Surcharge du circuit - rester vigilant lors de la connexion de l’équipement au circuit d’alimentation et

aux conséquences d’une surcharge des circuits sur la protection contre les surintensités et les câbles

d’alimentation.

Tenir compte des indications de la plaque nominale de l’appareil.

• Sécurité de la mise à la terre. Veiller à toujours garantir l’intégrité de la prise de mise à la terre. Faire

particulièrement attention aux connexions d’alimentation en dehors des branchements directs au circuit de

dérivation (par exemple à l’aide de multiprises).

This manual is related to the following products: