18.6. Disabling the ARC Function

It is possible to reset the assigned ARC filter.

Note

All the ARC filters assigned to output channels are reset through the operation below

The ARC filter cannot be reset for each output channel.

ARC operation indicator

Assignment switch

Hold down for 8 seconds.

0 – 3 seconds

M-864D

Lit

Flashing

3 – 8 seconds

Unlit

After 8 seconds

MONO INPUT 1

Assignment switch

Assignment indicator

1

2

Note: Use a fine-tipped object to press in the Assignment switch and the ARC switch.

Step 1. Turn off all the Assignment switches 1 – 4 of MONO INPUT 1 (assignment indicators go off).

Step 2. Hold down the ARC switch for 8 seconds.

The ARC operation indicator flashes rapidly after 3 seconds.

Continue to hold it down for 5 seconds.

The ARC operation indicator goes off and the ARC function is disabled.