beautypg.com

X10 operation, Manual lamp module control – Interlogix Simon XT Tabletop Installation Manual User Manual

Page 73

background image

Chapter 5:

Simon XT TableTop Control Panel Installation Manual

67

4. Press * and the panel voice identifies the alarm. If there is more than one

alarm in progress, the user must press * for the panel voice to identify them.

Note: You must terminate the call by pressing #. Otherwise, the panel may
not disconnect from the phone line for up to 2 minutes.

5. After all alarms have been identified, the panel announces Press # to exit.

6. Press # to terminate the call.

X10 operation

The following sections describe how to test X10 lamp, siren, appliance, and
universal module operation.

Manual lamp module control

Use the following methods to test manual lamp module control:

Control panel

Press the asterisk button (*) and the unit number of the lamp module using the
numeric buttons to test individual lamp modules 1 through 8. The panel responds
with Light # on/off. Press the asterisk button (*) twice to turn on all lamp modules.
Press the pound button (#) twice to turn off all lamp modules.

Keyfob

Press the Light button repeatedly to turn all lights on and off. The panel responds
with Lights on/off.

Remote handheld touchpad

Press the Lights on button and the unit number of the lamp module using the
numeric buttons to test individual lamp modules 1 through 8. The panel responds
with Light # on/off. Pressing the Lights on or Lights off button twice turns all the
lights on or off.

Simon XT TableTop touchpad

Press the Lights on button and the unit number of the lamp module using the
numeric buttons to test individual lamp modules 1 through 8. The panel responds
with Light # on/off. Pressing the Lights on or Lights off button twice turns all the
lights on or off.