Reporting – Interlogix Simon XT Tabletop Installation Manual User Manual
Page 51

Chapter 4:
Simon XT TableTop Control Panel Installation Manual
45
5. The panel displays Sn ## Grp ##
panel displays the sensor you want to delete. Press Enter.
6. The panel displays Deleted, then shows Delete sensor. Press Status twice to
exit.
Editing sensors
You can use this feature to change the group or name of a sensor that is already
in panel memory. The procedure is very similar to the procedure used to program
sensor information after a sensor is learned in. Pressing Disarm while editing
sensor text deletes all text for that sensor. Table 15 below provides sensor option
details.
Table 15: Sensors
Function
Default
Description
Learn sensors
Adds (learns) sensors to panel memory.
Delete sensors
Deletes sensors from panel memory.
Edit sensors
Edits sensor information in panel memory.
Reporting
Table 16 below and Table 17 on page 47 provide report option details.
Table 16: Reporting options
Function
Default Description
Opening
reports
Off
Determines whether the panel sends opening reports to a central station
whenever the system is disarmed (on), or not (off). User number will be
reported as zone number.
Keyfobs learned into zone 1 to 40 will report as zone they are learned into.
Dealer code = 44 Installer code = 45 Master code = 46
User code 1 = 47 User code 2 = 48 User code 3 = 49
User code 4 = 50 User code 5 = 51 User code 6 = 52
User code 7 = 53 User code 8 = 54 Duress code = 55