Interlogix Simon XT Tabletop Installation Manual User Manual
Page 60
Chapter 4:
54
Simon XT TableTop Control Panel Installation Manual
To program the housecode, do the following:
1. Press the scroll buttons until the panel displays System programming. Press
Enter.
2. The panel displays Enter code. Enter your access code and press Enter.
3. The panel displays Access codes. Press the scroll buttons until the panel
displays Light control. Press Enter.
4. The panel displays Set entry lights. Press the scroll buttons until the panel
displays Housecode
5. The letter flashes. Press the scroll buttons until the letter you want displays.
Press Enter to accept the new housecode.
6. The panel displays Housecode
program mode.
To program an entry-activated light, do the following:
1. Press the scroll buttons until the panel displays System programming. Press
Enter.
2. The panel displays Enter code. Enter your access code and press Enter.
3. The panel displays Access codes. Press the scroll buttons until the panel
displays Light control. Press Enter.
4. The panel displays Set entry lights. Press Enter.
5. The panel displays Entry light unit 1 on/off. Press the scroll buttons until the
unit number you want to program displays. Press Enter.
6. The panel displays Off, which will be flashing. Press the scroll buttons until
the panel displays On. Press Enter.
7. Press STATUS three times to exit program mode.
To program a sensor-activated light, do the following:
1. Press the scroll buttons until the panel displays System programming. Press
Enter.
2. The panel displays Enter code. Enter your access code and press Enter.
3. The panel displays Access codes. Press the scroll buttons until the panel
displays Light control. Press Enter.
4. The panel displays Set entry lights. Press the scroll buttons until the panel
displays Sensor light. Press Enter.
5. The panel displays Sn ##
until the panel displays the sensor number you want to activate. Press Enter.