Sensor testing – Interlogix Simon XT Tabletop Installation Manual User Manual
Page 67
Chapter 5:
Simon XT TableTop Control Panel Installation Manual
61
Table 27: Arming levels
Arming
level
Description
Indication
0
Subdisarms (master
access and duress codes
only), and bypasses 24-
hour intrusion sensors
(master access code
only). Fire sensors (group
26) cannot be
subdisarmed.
One beep indicates the system is subdisarmed. The
panel displays and speaks Subdisarmed. The Disarm
button blinks.
1
Disarm the system
One beep indicates the system is disarmed. The panel
displays and speaks Disarmed. The Disarm button
lights.
2
Arm doors and windows
Two beeps verify that door/window sensors are
armed. The panel displays Doors+Windows and
speaks Doors and windows on. The Doors+Windows
button lights.
3
Arm motion sensors
Three beeps verify that motion sensors are armed.
The panel displays Motions and speaks Motions on.
The Motions button lights.
4
Arm doors, windows, and
motion sensors
Four beeps verify that door/window and motion
sensors are armed. The panel displays Doors +
Windows & Motions and speaks Doors and windows
on, motions on. The Doors+Windows and Motions
buttons light.
Sensor testing
Test the sensors after all programming is completed and whenever a sensor-
related problem occurs.
Note: While the sensor test is a valuable installation and service tool, it only tests
sensor operation for the current conditions. You should perform a sensor test
after any change in environment, equipment, or programming.
Notify the central station you will be performing a test prior to starting the test. To
test the sensors, do the following:
1. Place all sensors in their secured (no alarm) state.
2. Go to the Sensor test option under the System tests menu, then press Enter.
The panel will prompt you to trip each sensor one at a time. You may follow the
panel prompting or test the sensors in any order. Use Table 28 on page 62 to trip
sensors