Light control (optional) – Interlogix Simon XT Tabletop Installation Manual User Manual
Page 59

Chapter 4:
Simon XT TableTop Control Panel Installation Manual
53
Table 23: Audio verification
Function
Default Description
Audio mode
Off
1 = Instant. Panel stays online with central station for an instant audio
session.
2 = Callback. Panel hangs up and waits for a callback from the central
station operator before starting an audio session.
Off = No audio verification.
Fire shutdown
Off
Determines whether system fire sirens are silenced during a two-way
audio session (on) or not (off). Beeps sound every 10 seconds while
sirens are silenced.
Panic talk
Off
Determines whether the central station operator can talk to the user
during a silent alarm (off) or just listen in on the premises (on). Silent
alarms occur when sensors learned into groups 02 or 03 are tripped,
when the duress code is entered, or when the panel Police button is
pressed and the Silent panel police panic option is turned on.
Vox Rx gain
06
Determines the receiver gain level during two-way audio sessions. If
the vox is switching the speaker on when the central station operator
is not talking, lower both this setting and the vox microphone gain
setting. If the vox is not switching the speaker on when the central
station operator is talking, raise this setting and lower the vox
microphone gain setting. Changing this setting does not affect
speaker volume.
Vox mic gain
24
Sets the microphone gain (sensitivity) that triggers the voice-activated
switching (vox). Room size, acoustics, and furnishings where the
panel or Interrogator 200 are located will influence the setting. Gain
range is 01 (lowest) to 64 (highest).
Vox mic gain
rng
64
Sets the gain range for voice-activated switching (vox). Range is 01
(lowest) to 64 (highest). For best results, this option should be set
equal to or greater than vox microphone gain.
Note: This option works in conjunction with vox microphone gain. It is
important to follow the setting recommendations as described to
achieve acceptable operation.
Manual mic
gain
64
Determines the gain level (sensitivity) during two-way audio sessions
when audio mode is set to 0 or 1 (speak). Room size, acoustics, and
furnishings where the panel is located will influence the setting. Gain
range is 01 (lowest) to 64 (highest).
Light control (optional)
If your system uses optional X10 modules, you can program them to control
lights.
X10 module operation
Use the following procedure to program X10 module operations into panel
memory.