Two-way voice operation, Voice event notification – Interlogix Simon XT Tabletop Installation Manual User Manual
Page 72
Chapter 5:
66
Simon XT TableTop Control Panel Installation Manual
Arm or disarm from
Reports as user
Access codes 1 to 8
47 to 54
Duress code
55
Two-way voice operation
For the central station operator to initiate an audio session, see Table 32 below
and do the following:
1. After the panel has completed reporting the alarm, pick up the CS phone and
press the * button to start the audio session.
2. Press 1 or 0 to speak, 2 for vox operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Note: Panel voice announcements are silenced during AVM sessions. If the
operator does not terminate the session correctly, panel announcements may not
occur for up to 90 seconds after the operator hangs up.
Table 32: Audio verification set
Phone
buttons
Function
0 and 1
Speak
2
Vox operation
3 or 6
Listen
7
Extend session for 90 more seconds
88
Terminates session with call back (the panel answers on the first ring if called
within five minutes)
99
Terminates session with no call back
Voice event notification
Testing this feature requires two people; one at the alarm site and the other at
the location the panel is programmed to call.
To test voice event notification, do the following:
1. Contact the central monitoring station (if system is monitored) to inform them
you are testing the system and not to dispatch authorities.
2. At the system site, put the system into an alarm condition.
3. At the calling location, pick up the phone after it starts ringing. You should
hear the panel voice announce Press star for alarm.