beautypg.com

Two-way voice operation, Voice event notification – Interlogix Simon XT Tabletop Installation Manual User Manual

Page 72

background image

Chapter 5:

66

Simon XT TableTop Control Panel Installation Manual

Arm or disarm from

Reports as user

Access codes 1 to 8

47 to 54

Duress code

55

Two-way voice operation

For the central station operator to initiate an audio session, see Table 32 below
and do the following:

1. After the panel has completed reporting the alarm, pick up the CS phone and

press the * button to start the audio session.

2. Press 1 or 0 to speak, 2 for vox operation, and 3 or 6 to listen.

3. Press 99 to terminate the session.

Note: Panel voice announcements are silenced during AVM sessions. If the
operator does not terminate the session correctly, panel announcements may not
occur for up to 90 seconds after the operator hangs up.

Table 32: Audio verification set

Phone
buttons

Function

0 and 1

Speak

2

Vox operation

3 or 6

Listen

7

Extend session for 90 more seconds

88

Terminates session with call back (the panel answers on the first ring if called
within five minutes)

99

Terminates session with no call back

Voice event notification

Testing this feature requires two people; one at the alarm site and the other at
the location the panel is programmed to call.

To test voice event notification, do the following:

1. Contact the central monitoring station (if system is monitored) to inform them

you are testing the system and not to dispatch authorities.

2. At the system site, put the system into an alarm condition.

3. At the calling location, pick up the phone after it starts ringing. You should

hear the panel voice announce Press star for alarm.