Test the panel by pressing the buttons as described in Table 26 below and
Table 27 on page 61 provides a list of the arming levels.
Note: An access code is required when arming if the Secure arming option is on
Table 26: Control panel test sequence
Button
Function tested
Test
Correct result
Doors+Windows
The panel arms door
and window sensors.
Press Doors+Windows a
second time to eliminate the
programmed entry delay.
The button will blink
when no entry delay
is on.
Motions
The panel will arm
motion sensors.
Press Motions a second time to
turn latchkey on.
The button blinks
when latchkey is on.
Disarm
The panel will prompt
you to enter an
access code.
Enter the appropriate code.
The panel will disarm
doors, windows, and
motion sensors.
Status
Press Status for panel to
display and speak the system
status.
Police
Press and hold Police or press
button twice quickly to activate
a police or emergency alarm.
Fire
Press and hold Fire or press
button twice quickly to activate
a fire emergency alarm.
Emergency
Press and hold Emergency or
press button twice quickly to
activate a nonmedical
emergency alarm.
Note: Forty keypresses for invalid codes (ten invalid 4-digit codes, for example)
will cause a system access alarm. The alarm locks all touchpads, except
keyfobs, for 90 seconds.