beautypg.com

Interlogix Simon XT Tabletop Installation Manual User Manual

Page 57

background image

Chapter 4:

Simon XT TableTop Control Panel Installation Manual

51

Table 21: Siren options

Function

Default Description

Piezo beeps

On

This option determines whether the panel piezo produces beeps
based on system activity (on) or is silent (off).

Panel voice

On

When on, arming level changes will be spoken.

Panel piezo
alarm

On

Determines whether the panel piezo emits alarm sounds (on) or not
(off).

Trouble beeps

On

Determines whether the panel, X10, and hardwired interior sirens
sound six beeps every minute when a trouble condition occurs (on) or
not (off). The following conditions cause trouble beeps:

AC power failure (when AC power failure report is on) low CPU

battery

Sensor failure (supervisory)

Sensor trouble (low battery, tamper, etc.)

Fail to communicate

Restoration of power

No Activity timer has timed out. Trouble beeps continue for five

minutes and if the panel does not see activity, trouble beeps stop

and the panel reports the no activity to the central station.

You can silence trouble beeps by arming or disarming the system or
by pressing the Status button. Trouble beeps resume four hours later
if the trouble condition is not cleared.

Voice chime

Off

Determines whether the panel announces the sensor name.

1 = Sensor name

2 = Loud ding-dong bell

3 = Soft ding-dong bell

Off = No sound

Status beeps
vol.

7

Determines the panel piezo volume level for status sounds such as
arming, trouble, and status beeps. Volume range is 1 (lowest) to 10
(highest).

HW siren sup.

Off

Determines whether the panel monitors hardwired sirens for open
conditions (on) or not (off). If this option is turned on, sirens connected
to the panel terminals require an EOL resistor in the wire circuit. (See
“Interior sirens” on page 22 for siren wiring.) If this option is turned off,
EOL resistors are not required whether sirens are connected or not.

Speaker
volume

8

Sets the volume of voice messages from the panel speaker. Volume
range is 1 (lowest) to 8 (highest).

Silent police
panic

Off

Determines whether pressing the panel police panic button causes an
audible (off) or silent (on) alarm.

Panel tamper
alarm

Off

Determines whether the panel activates a tamper alarm anytime the
cover is opened (On) or only when the system is armed (off).