Interlogix Simon XT Tabletop Installation Manual User Manual
Page 62
Chapter 4:
56
Simon XT TableTop Control Panel Installation Manual
Table 24 below provides light control option details.
Table 24: Light control
Function
Default Description
Set entry
lights:
Entry light unit,
1 through 8
Off
This menu allows the user to set X-10 lights with
unit numbers from 1 to 8 as entry lights (on).
Sensor light # 01 to 40
In this menu, each enrolled sensor can be
associated with an X-10 light with unit number from
1 to 8 (or Off for no association).
Light
schedules
Light schedule,
1 through 8
Off
In this menu, a light schedule can be programmed
for each X-10 module with unit number from 1 to 8.
Housecode
A
Lock interval
(Light) lock
interval
Blank
This option sets the daily lockout time during which
sensor trips do not activate associated X-10 lights
System tests
Table 25 below provides system test option details.
Table 25: System test
Function
Default Description
System tests
Comm test
The communication test is used to check the phone
communication between the panel and the central
station or voice report destination.
Sensor test
The sensor test is used to check proper sensor
operation.
System
download
This feature initiates a phone call from the panel to
the Enterprise Downloader.
Resetting memory to the factory defaults
To reset the panel to its factory defaults, do the following:
1. Unplug the transformer and disconnect the battery.
2. Press and hold the four arming/status buttons (Doors+Windows, Motions,
Disarm, and Status) on the front of the panel.
3. Restore power to the panel, plugging in the AC transformer while holding the
four buttons.
4. Release the buttons.
5. Remove A power.