168 rmon event – Interlogix NS3702-24P-4S Command Line Guide User Manual
Page 268
-268-
Event to fire on rising threshold crossing
falling-threshold
Configure the falling threshold
falling threshold value
Event to fire on falling threshold crossing
both
Trigger alarm when the first value is larger than the rising threshold or less than the falling threshold (default)
falling
Trigger alarm when the first value is less than the falling threshold
rising
Trigger alarm when the first value is larger than the rising threshold
Default:
None
Usage Guide:
To configure the Alarm of RMON
Example:
To configure the Alarm (below table) of RMON
Switch# configure terminal
Switch ( config)# rmon alarm 1 .1.3.6.1.2.1.2.2.1.10.15 50 absolute rising-threshold
1000 1 falling-threshold 520 1 falling
4.2.168 rmon event
Command:
rmon event
rmon Remote Monitoring
event
Configure an RMON event
description Specify a description of the event
log
Generate RMON log when the event fires
trap Generate SNMP trap when the event fires
Default:
None