129 network-clock selector – Interlogix NS3702-24P-4S Command Line Guide User Manual
Page 235

-235-
option
EEC options
eec1
EEC1: DPLL bandwidth = 3,5 Hz, pull-in range = +/-12 ppm
eec2
EEC2: DPLL bandwidth = 0,1 Hz, pull-in range = +/-12 ppm
Default:
None
Usage Guide:
To configure EEC options of network-clock
Example:
To configure EEC options (eec1) of network-clock
Switch# configure terminal
Switch (config)# network-clock option eec1
4.2.129 network-clock selector
Command:
network-clock selector { { manual clk-source
nonrevertive | revertive | holdover | freerun }
network-clock
net work-clock
selector
Selection mode of nominated clock sources
freerun
Selector is forced in free run
holdover
Selector is forced in holdover
manual
Selector is manually set to the chosen clock source
Cl ock source number
clk-source
clk-source - commands related to a specific clock source
nonrevertive
Selector is automatically selecting the best clock source - non revertively
revertive
Selector is automatically selecting the best clock source - revertively
selected
Selector is manually set to the pt. selected clocfk source (not possible in unlocked mode)
Default:
None
Usage Guide:
To configure Clock Selection Mode of network-clock
Example: