Key features and specifications, Key features, Specifications – Flintec FAD-30 User Manual

Page 7

background image

FAD-30 Technical Manual, Rev. 1.06 December 2012

Page 7 of 48

3.2. Key features and Specifications

Key Features

F

A

D

-30

F

A

D

-30

MB

F

A

D

-30

P

B

F

A

D

-30

P

N

F

A

D

-30

E

N

F

A

D

-30

CO

Bipolar signal input in Force and Count modes

Yes

Yes

Yes

Yes

Yes

Yes

500 to 100 000 counts external resolution at calibrated data

Yes

Yes

Yes

Yes

Yes

Yes

Unipolar 1 million and bipolar 2 million counts is adjusted and filtered
to external resolution in count mode

Yes

Yes

Yes

Yes

Yes

Yes

High internal resolution up to 8 million counts

Yes

Yes

Yes

Yes

Yes

Yes

Up to 800 conversions per second

Yes

Yes

Yes

Yes

Yes

Yes

Standard Serial interface RS-232C

Yes

Yes

Yes

Yes

Yes

Yes

Standard Serial interface RS-485A

Yes

Yes

No

No

No

No

Modbus RTU interface

No

Yes

No

No

No

No

Profibus DP-V1 interface

No

No

Yes

No

No

No

ProfiNet interface

No

No

No

Yes

No

No

Ethernet (Modbus TCP/IP or BSI) interface

No

No

No

No

Yes

No

CANopen interface

No

No

No

No

No

Yes

Continuous data output

Yes

Yes

No

No

No

No

BSI data interface

Yes

Yes

No

No

No

No

Bus address selection by setup switch (from 0 to 7)

Yes

Yes

Yes

No

No

Yes

Setup by Flintec xFace PC software

Yes

Yes

Yes

Yes

Yes

Yes

Auto-zero tracking and auto-zero at power-up

Yes

Yes Yes

Yes

Yes

Yes

Motion detection

Yes

Yes

Yes

Yes

Yes

Yes

Zeroing and Taring by bus commands

Yes

Yes

Yes

Yes

Yes

Yes

Adaptive digital filter for fast and stable reading

Yes

Yes

Yes

Yes

Yes

Yes

Up to 6 load cells (350 Ω) or 18 load cells (1100 Ω)

Yes

Yes

Yes

Yes

Yes

Yes

Electronic calibration (eCal) without test weights

Yes

Yes

Yes

Yes

Yes

Yes

Zero and Span calibrations over bus interface

Yes

Yes

Yes

Yes

Yes

Yes

Zero adjustment

Yes

Yes

Yes

Yes

Yes

Yes

Span adjustment with test weights

Yes

Yes

Yes

Yes

Yes

Yes

Span adjustment with temporary zeroing for unloaded tanks

Yes

Yes

Yes

Yes

Yes

Yes

Power-on testing with setup switch

Yes

Yes

Yes

Yes

Yes

Yes

24 V DC power supply (11 to 28 V DC input voltage range)

Yes

Yes

Yes

Yes

Yes

Yes

Specifications

A/D Converter:

A/D converter type:

24 bit Delta-Sigma radiometric with integral analog and digital filters

Analog input range:

0 mV to +18 mV ( unipolar ) ; - 18 mV to +18 mV ( bipolar )

Linearity:

< 0.0015 % FS

Temperature coefficient:

< 2 ppm/°C

Min. input per vsi

0.1 μV/d (non approved)

Conversion rate:

Up to 800 measurement values per second

Internal resolution:

Up to 8 million counts

External resolution

Up to 100 000 counts (weight value, force, torque) respective
1 million raw counts (unipolar) respective 2 million counts (bipolar)

Calibration and Weighing Functions:

Calibration:

Electronic calibration without test weights (eCal) or calibration by test weights

Digital filter:

10 step programmable adaptive filter

Weighing functions:

Tare, zero, auto zero tracking, motion detection, auto-zero at power-up, save
tare at power-off, increased resolution

Load cells:

Excitation:

5 V DC at 58...1200 Ω, max. 100 mA

Number of load cells:

Up to 6 load cells à 350 Ω or 18 load cells à 1100 Ω in parallel

Connection:

4- or 6-wire technique, cable length 250 m/mm² for 6-wire connection