5.11. Profibus and ProfiNet Data Structure (for FAD-30Px only)
Hardware Configuration Hint
To install the FAD-30PB or FAD-30PN into the PLC Hardware Configuration use the GSD file memory parts to
create exactly the following memory structure:
Input 2 Words
Output 2 Words
Input 2 Words
Input 2 Words
Output 2 Words
Output 2 Words
FAD-30Px Output to PLC Input
Dword
D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1st
Dword
Reserved
2nd
Dword
W31
MSB
W30 W29 W28 W27 W26 W25
W24 W23 W22 W21 W20 W19 W18 W17 W16
W15 W14 W13 W12 W11 W10
W9
W8
W7
W6
W5
W4
W3
W2
W1
W0
LSB
3rd
Dword
Not in use
Error codes of converter Not in use
Op.
mode
Zero
range
Gross
Net
MD
Read command response
Cmd
Flag
FAD-30Px Output to PLC Input 2
nd
Dword
The 2
nd
Dword contains the weight value respective the calibration information according to the
“read command
response” (Refer to PLC Output to FAD-30Px Input 3rd Dword).
FAD-30Px Output to PLC Input 3
rd
Dword
Bit no.
3
rd
Dword Description
D31…D16
Not in use
D15…D12
Error codes of
converter
0000
No error found
0001
ADC out
0010
ADC over
0011
ADC under
0100
System error
0101
In setup mode
0110
Low/High voltage error
0111
Instrument not found
D11…D10
Not in use
D9
Operation mode
0
Weight & Force Mode
1
Count Mode
D8
Zero range
0
Weight is out of zero range
1
Weight is in zero range
D7
Indication
0
Gross
1
Net
D6
MD
–
Motion detection
0
Stable
1
Unstable
D5
D4
D3
D2
D1
Read command
response
00000
Indicated weight
00001
Gross weight
00010
Tare weight
00011
Indicated weight (floating point type)
00100
Gross weight (floating point type)
00101
Tare weight (floating point type)
10000
Calibration Status (Refer to table 8.2)
D0
CMD flag
A change of Flag indicates: The command is applied successfully