5.12. CANopen Data Structure (for FAD-30CO only)

Hardware Configuration Hint

To install the FAD-30CO into the PLC Hardware Configuration use the ESD file memory parts to create exactly
the following memory structure:

Input 2 Words

Output 2 Words

Input 2 Words

Input 2 Words

Output 2 Words

Output 2 Words

FAD-30CO Output to PLC Input

Dword

D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16

D15 D14 D13 D12 D11 D10

D9

D8

D7

D6

D5

D4

D3

D2

D1

D0

TxPDO 1
(T_DW1)

reserved

TxPDO 2
(T_DW2)

W31

MSB

W30 W29 W28 W27 W26 W25 W24 W23 W22 W21 W20 W19 W18 W17 W16

W15 W14 W13 W12 W11 W10 W9

W8

W7

W6

W5

W4

W3

W2

W1

W0

LSB

TxPDO 3
(T_DW3)

Not in use

Error codes of converter Not in use

Op.

mode

Zero

range

Gross

Net

MD

Read command response

Cmd

Flag

FAD-30CO Output to PLC Input T_DW2

T_DW2 contains the weight value respective the calibration information according to the

“read command

response” (Refer to FAD-30COOutput to PLC Input T_DW3).

FAD-30CO Output to PLC Input T_DW3

Bit no.

T_DW3 Description

D31…D16

Not in use

D15…D12

Error codes of
converter

0000

No error found

0001

ADC out

0010

ADC over

0011

ADC under

0100

System error

0101

In setup mode

0110

Low/High voltage error

0111

Instrument not found

D11…D10

Not in use

D9

Operation mode

0

Weight & Force Mode

1

Count Mode

D8

Zero range

0

Weight is out of zero range

1

Weight is in zero range

D7

Indication

0

Gross

1

Net

D6

MD

Motion detection

0

Stable

1

Unstable

D5
D4
D3
D2
D1

Read command
response

00000 Indicated weight
00001 Gross weight
00010 Tare weight
00011 Indicated weight (floating point type)
00100 Gross weight (floating point type)
00101 Tare weight (floating point type)
10000 Calibration Status (Refer to table 8.2)

D0

CMD flag

A change of the flag indicates: New CMD is applied successfully