beautypg.com

Commands and responses – Flintec FAD-30 User Manual

Page 21

background image

FAD-30 Technical Manual, Rev. 1.06 December 2012

Page 21 of 48

Commands and Responses

A

Read all weight data

Command:

[ADR][A]

Response:

[ADR][A][STATUS][SIGN][NET W][SIGN][TARE W][SIGN][GROSS W]

Example:

Command :

01A

Response :

01AS+000123.4+000111.1+000234.5

01AD+000123.4+000111.1+000234.5

01AO

( ADC out error )

Comments:

The response is net, tare and gross weight values or error status. All weight data will be
transmitted immediately after receiving the command.

B

Read Gross weight

Command:

[ADR][B]

Response:

[ADR][B][STATUS][SIGN][WEIGHT VALUE]

Example:

Command:

01B

Response:

01BS+000123.4

(gross weight is stable and 123.4)

01BD+000123.4

(gross weight is unstable and 123.4)

01B

(under load)

Comments:

The response is the gross weight value (stable or unstable) or error status. Gross weight data
will be transmitted immediately after receiving command.

C

Clear the tare memory

Command:

[ADR][C]

Response:

[ADR][C][A]

(Cleared and the scale is in gross mode)

[ADR][C][X]

(Clear command is unavailable in count mode)

Comments:

The response status is always Ack in weighing or force mode and always X in count mode.

D

Read Count value immediately

Command:

[ADR][D]

Response:

[ADR][D][STATUS][SIGN][COUNT VALUE]

Example:

Command:

01D

Response:

01DD+00123400

01DO

(ADC out error)

01DX

(Not in count mode)

Comments:

Count value will be sent immediately.

I

Read indicated weight

Command:

[ADR][I]

Response:

[ADR][I][STATUS][SIGN][WEIGHT VALUE]

Example:

Command:

01I

Response:

01IS+000123.4

( weight is stable and 123.4 )

01ID+000123.4

( weight is unstable and 123.4 )

01I+

( overload )

Comments:

The response is the indicated weight value (stable or unstable). It will be transmitted
immediately after receiving the command. The weight value may be in gross or net.

P

Print :Read the stable weight

Command:

[ADR][P]

Response:

[ADR][P][STATUS][SIGN][WEIGHT VALUE]

Example:

Command:

01P

Response:

01PS+000123.4

(weight is stable and 123.4) or

01PN

(could not print)

Comments:

Checks status and it must be stable. Else Nack status will be sent. There is no time period for
stability checking. Status can be Stable or Nack.