beautypg.com

Electrical connections, Ethernet connector (rj45), Figure 9.2 – hub connection – Flintec FAD-30 User Manual

Page 41: Figure 9.3 – direct pc connection with cross cable, Ethernet interface

background image

FAD-30 Technical Manual, Rev. 1.06 December 2012

Page 41 of 48

9.2. Electrical Connections

Ethernet and RS-232C connections are shown in figure 9.2 to 9.4.

Ethernet Connector (RJ45)

Pin

Signal

DIR

Description

1

TX+

Out

Differential Ethernet transmit data +

2

TX

Out

Differential Ethernet transmit data

3

RX+

In

Differential Ethernet receive data +

6

RX

In

Differential Ethernet receive data

4

Not used

Terminated

5

Not used

Terminated

7

Not used

Terminated

8

Not used

Terminated

Shield

Chassis ground

The HUB connection cabling will be a direct connection as shown below:

Figure 9.2

– HUB connection

The PC connection cabling will be done via cross cable as shown below:

Figure 9.3

– Direct PC connection with cross cable

FAD-30EN interface connections are shown below:

Figure 9.4

– FAD-30EN interface connections

RS-232C Serial Interface

Use

Setup via xFace

Baud rate

9600 bps

Length and parity

8 bit, no parity

Start / Stop bits

1 start bit and 1stop bit

Ethernet Interface

Use

Ethernet interface with PC or PLC

Data format

Modbus TCP/IP

Ethernet

The Ethernet interface operates at 10Mbit, half duplex

Warning: Connect the shield to the reference ground or shield pin of the power connector.