Toshiba TEC EM1-31059 User Manual
Page 104
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

12. ERROR MESSAGE TABLE
EMI-31059
Label Issue Mode
• Label Issue Mode
Control lock: REG ./MARK DOWN/REWRAP
Message
Cause
Solution
DATA ENTRY ERROR
Error in key input
Depress the C key, and re-input.
PLU NOT FOUND
The PLU# being called out is not
registered.
Depress the C key, and check the
PLU data.
TOTALS OVERFLOW
GRAND TOTAL or PLU TOTAL
memory has overflowed at the time
of issuing a label.
Depress the C key, and turn the
control lock at “Z” position. Then
sum up the overflowing memory.
PLU DATA ERROR
Error in PLU data.
Depress the key, and check the
PLU data.
PRT FAILURE
Printer trouble
1. Check that the label and print
head are set correctly.
2. If the label home position is
misalianed, press the I FEED
key.
CASSETTE ERROR
Label cassette is not set correctly.
Set the cassette correctly.
Cassette switch is not set correctly.
Set the cassette switch correctly.
Setting of control lock position and
cassette switch is not correct.
When control lock position is set to
other than “X” or “Z”, set the
cassette
switch
to
“LABEL
POSITION”.
LABEL SENSE ERR.
The label interrupts the sensors.
Depress the key, then the
FEED I key and remove the label.
• Read and Reset Mode
Control lock: X (read)/Z (reset)
Message
Cause
Solution
PLU NOT FOUND
Corresponding PLU# or UPC# is
not registered.
Depress the key, and enter the
correct PLU#.
NO REGISTED
There is no combination report
setting data.
Depress the key, and check the
combination report tables.
PRT FAILURE
Printer trouble.
Same as in the label issue mode.
CASSETTE ERROR
Label cassette is not set correctly.
Set the cassette correctly.
LABEL SENSE ERR.
The label interrupts the sensors.
Depress the key, then the
FEED
I
key and remove the label.
1 2 - 3