Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

• Timing chart
ON
OFF
H--- H
150mS
800mS
When DTSS function is ON.
ON OFF
rum
150mS lOOmS
4-10. AUTOMATIC POWER OFF
This transceiver also provides an Automatic Power OFF
circuit. The circuit action is described below. (Initial
state is ON.)
1.
A 5 second audio confirmation alert will sound after
59 minutes if no signal has been received and if you
have not performed any operation.
2.
1 minute after this alert signal the transceiver will
shut
itself
off
except
for
enough
power
to
show
“APO” in the display.
3. When the APO operates and the transceiver is shut
off after
60 minutes, the transceiver
can be
reactivated
by
pressing
the
MONI
switch,
or
by
turning the POWER switch OFF and back ON.
4. To turn the APO function OFF/ON, press the CALL key
while turning on the POWER switch.
Note
The function can not be activated during scan or
Tone Alert system operation.
To conserve battery life even more simply turn the
transceiver OFF when you are not using it.