• Changing Transmitter Output Power
The EL-L-H switch allows you to select three different
transmitter output power levels.
1. H (High power)
Set the switch to this position for maximum output
power. The actual transmitter output power for this
unit depends on the power supply being used.
2. L (Low power)
Set the switch to this position for 0.5 W regardless of
the voltage.
3. EL (Economic low power)
Set the switch to this position for 20 mW regardless
of the voltage.
Set
the
switch
to
L
for
short-distance
communication
and
to
EL
for
line-of-sight
short-distance
communica
tion. This will conserve the battery.
MODEL
OUTPUT POWER
High power
Low power
Economic
Low power
TH-26A/26AT/26E
TH-46A/46AT/46E
PB-8. 11
12V
GOOmAh
5 W
5 W
0.5W
20mW
PB-7
7.2V
1 lOOmAh
2.5W
2 W
PB-6, 9, 10
7.2V
GOOmAh
PB-5
7.2V
200mAh
PB-11
6V
1200mAh
2 W
1,5W
BT-6
9V
Alkaline
batteries
2.5W
2 W
BT-7
6V
1 W
1 W
External power supply
13.8 VDC
5 W
5