I. TROUBLE SHOOTING

General Trouble Shooting

CAUTtON:

.

Always disconnect the dishwashers from the electrical power source before adjusting or replacing
components.

PROBLEM

POSSIBLE CAUSE

ACTION

Dishes not clean.

Dishwasher will not

operate when turned on..

Dishwasher

automatically

repeats with door latched

Dishwasher runs with
door open

1.

No power to dishwasher.

2 Open circuit between power source

and timer

3-, Loose terminal connections at door

switch arrd/or timer terminals,

4.

Defective door switch

5.

Defective selector switch.

6.

Defective timer motor circuits.

7

Defective start switch.

8. Main motor defective.

1,

Start switch contacts sticking ciosed.

2- A grounded timer motor combined with

reverse polarity connection at junction
box Of wall receptacle causing the "hot"
side of the circuit to bypass "off
switches in the timer.

3,

Grounded thermostat with reverse

polarity

4,

Broken slides inside of selector switch
(rapid advance timer only).

1.

Door switch defective.

2.

Terminals shorted to each other at the

door switch,

3.

Latching handle turned to the "ON"

position.

Grounded elsctricsl component
combined with reverse polarity
connection at function box or wall

receptacle.

Refer to introductory section at
beginrtlng of this manual,

1.

Check electrical outlet or connection

to junction box on built-in,

2 Check wiring and/or povs'er cords,.

3.

Repair as needed,

4.

Check continuity.

B„ Check continuity,

6. Refer to Timer Testing.

Applies to models with a rapid advance

timer. Check continuity.

8. Refer

to Motor Testing.

1„ Repiace start switch.

2,

Repiace timer, Refer to installation
Instructions for proper Blectricai

connection and grounding of power

receptacles.

3,

Replace thermostat. Check electrical

connection

4,

Refer to wiriftg diagram and check
selector switch circuitry.

1. Check continuity.

2.

Repiace defective parts.

3.

Check safety tab, which prevents
turning handle Into run position with

door open.

4.

Replace defective component. Refer
to Installation Instruction for proper
electrical connection and grounding

of power receptacle.