GASKET
607709
■GASKET 807710
locating
pin
CLAMPING RING
807712
PUMP HOUSING
807711
FIGURE 40
RBpIscing Pump und Motor Assembly (Msnufsciur&d in 1978 or Lutar)
1. Replace 807710 gasket
DO NOT
try to re-use origina! gasket. Be sure ridges on gasket face downward
2
5
6
.
Place pump and motor assembly in mounting hole in tub bottom. Be sure ports on pump housing are adjacent
to connecting ends of drain and recirculating hoses
Join together the two halves of the clamping ring on the pump housing Make sure the locating pins in the clamping
ring halves are inserted in the holes in the pump housing. The joined ring wil! stay in position on the pump housing
when R is properly assembled.
Install the pump mounting screws.
IMPORTANT: Install one screw on each side of the ring FIRST
See Figure
41
Attach hoses to pump housing ports. Secure damps with clamp screw on underside of hose
Connect motor leads disconnected in Step #4 in "Removing Pump and Motor Assembly.
7, Replace lower spray arm, lower rack, toe plate, and access panel
NSTAIL THESE SCREWS FIRST
JOINT-
FIGURE 41
4 1