This section describes major error messages displayed during operations and the remedies when the

messages are displayed.

Error message

Cause

Remedy

Current SL-V system information mismatches
the last upload settings.
The last uploaded settings will be downloaded
or be verified with. Continue?

The system information sent to the
SL-V main unit and the actual
configuration of the SL-V is different.

Check the configuration
of the SL-V.

The amount of light received is not correctly
shown due to the unit mismatch.

The transmitter is not connected.

The transmitter and receiver are not
the same model.

Connect a transmitter.

Connect a transmitter
and receiver of the
same model.

Monitoring cannot be done due to the main-unit
mismatch.

The type and the number of beam
axes from the connected SL-V Series
(main unit) are different from the
settings of the main unit on the SL-V
Configurator.

Conform the settings of
the main unit on the SL-V
Configurator to the
settings on the SL-V.

Units mismatch.

The system information on the SL-V
Configurator differs from the
information for the SL-V.

Conform the system
information on the SL-V
Configurator to the
configuration of the SL-V.

SL-V doesn't have an initial Password.

A password has already been set on
the SL-V.

When you want to change
the password, refer to

"4-6 Changing the

Password" (Page 4-8). (If
you forget the password,
it cannot be changed.)