3-2

Non Safety Related Configuration

3-5

Co
nfig

urat

ion
of Eac

h

Fu
nct
ion

3

SL-VH1S-NO3-E

It cannot be configured to Built-in Indicator Mode when the muting bank function is enabled.

"3-4 Muting Area" (Page 3-7)

When the State Indicator Mode is set, normal operation is performed each time immediately after

the power is turned on. When OSSD ON state continues five seconds or more, the mode is

switched to the State Indicator Mode.

* Configuration of the State Indicator Mode

1

Select the State Indicator Mode, and click [Detail] button.

[Center Indicator] dialog is displayed.

2

Click [OK] button.

Configuration will be applied and it will return to the Main window.

Multiple lighting conditions cannot be assigned to a single state.

Center Indicator

Item

Contents of

Configuration

Description

Center Indicator

Normal (Default)

Normal operation is performed.

Built-In Indicator mode

ON/OFF of the center indicator will be controlled by
external input.

OFF

Center indicator will be constantly turned OFF.

State Indicator Mode*

Lighting of the center indicator can be selected
depending on the state of the SL-V.

(When State-
Indicator Mode is
selected)*

Light in
red

OSSD OFF / WAIT input
active / None

Select the state to make the center indicator to turn on
in red.

Blinking
in green

Muting / Override /
WAIT input active / None

Select the state to make the center indicator to flash in
green.

Light in
green

OSSD ON / None

Select the state to make the center indicator to turn on
in green.

Note

Item

Description

(1) State Window

This displays the state of the SL-V that can be assigned.

(2) Cancel Assign Button

This will cancel the assigning selected in (4).

(3) Assign Button

This will assign the state selected in (1).

(4) Lighting Condition

This will display how it will be light.

(5) OK Button

This will apply the configuration and close the dialog.

(6) Cancel Button

This will not apply the configuration and close the dialog.

(1)

(4)

(6)

(5)

(3)

(2)

Note