Non Safety Related Configuration

By clicking on the [Non Safety-related Configuration] tab, the configuration for the functions useful to

control, such as state information output or how the indicator is turned on can be configured.

Emitting Frequency

Item

Contents of

Configuration

Description

Emitting Frequency

TYPE-A (Default) /
TYPE-B

Mutual interference is reduced by changing the
transmitter frequency.

Alert Output

Item

Contents of

Configuration

Description

Alert monitoring time

1 sec / 5 sec (Default) /
10 sec

The alert output turns ON if the received light intensity
continues to fall below the threshold value for more
than the period of time set here.

State Information Output

Item

Contents of

Configuration

Description

Output style

Normal mode (Default) /
Simple mode

This will select the output mode of the state information
output.

Pulse Speed

Normal (Default)

ON/OFF width of the pulse will be 20ms each.

Slow

ON/OFF width of the pulse will be 100ms each.