2-3
Startup and Exiting the
2-6
Basic Operat
ion
2
SL-VH1S-NO2-E
When "Create New Configuration" is selected
When "Create New Configuration" is selected, the [System Information] dialog is displayed.
The
create the configuration, and clicking on [OK].
Contents configured here can be changed later by clicking on the [System] button on the Toolbar.
"4-2 Changing the Type Configuration" (Page 4-3)
Item
Description
(1) Main Unit Type
(No need to select.)
(2) Beam Axes for Main Unit
Enter the number of beam axes for main unit.
(3) Beam Axes for Sub Unit
Place a check in the check box and select the number of beam axes when using a
sub unit.
(4) Note
A memo can be affixed to each unit. (Up to 10 double byte characters)
(5) Store system information
Number of beam axes for the sub unit 1 and the sub unit 2 can be memorized in the
main unit of the SL-V. By uploading the configuration with this option on,
number of beam axes as it was configured. (It will go to lockout condition.)
(6) Download unit information
from SL-V
This allows acquiring the system information of the connected SL-V.
(Model configuration and Note that is being configured will be discarded.)
(7) Note
A Note can be added to the system itself. (Up to 1024 double-byte characters)
(8) OK button
(1)
(2)
(3)
(5)
(7)
(4)
(6)
(8)
Reference