Sensor amplifier (slot 1 to 4), Communication methods – KEYENCE DL-PN1 User Manual
Page 9
7
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
*1 External input request to the sensor amplifiers connected to the DL-PN1 (Slot 0) can
be executed en bloc. (Smart Access function)
Functions assigned to the external input request 1 to 4 are as follows:
•
External input request 1: ZERO SHIFT input
•
External input request 2: RESET input
•
External input request 3: TIMING input
•
External input request 4: Adjust input
Functions assigned to the external input request 1 to 4 can be changed.
Refer to the IB series user's manual.
Sensor amplifier (Slot 1 to 4)
Output
Functions assigned to the external input request 1 to 4 are as follows:
•
External input request 1: ZERO SHIFT input
•
External input request 2: RESET input
•
External input request 3: TIMING input
•
External input request 4: Adjust input
Functions assigned to the external input request 1 to 4 can be changed.
Refer to the IB series user's manual.
Communication Methods
The following describes how the I/O controller communicates with the DL-PN1 (data I/O
communication).
•
"Reading an output from a sensor amplifier" (page 8)
•
"Entering an external input to a sensor amplifier" (page 8)
•
"Reading comparator values (P.V. values) from sensor amplifiers" (page 9)
Address
Bit
Function name
Description
Value
1 to 4
0
External input request 1
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
1
External input request 2
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
2
External input request 3
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
3
External input request 4
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
4
Reserved for system
-
-
5
Reserved for system
-
-
6
Reserved for system
-
-
7
Reserved for system
-
-