Data I/O communication device map (DL-PN1 PROFINET I/O controller)

DL-PN1 (Slot 0)

Input

Sensor amplifier (Slot 1 to 4)

Input

Address

Bit

Function name

Description

Value

0

0

Reserved for system

-

-

1

Reserved for system

-

-

2

Comparator value property

Stores the comparator value status.

0: Normal
1: Disabled status
“----”, “FFFF”, or “-FFFF”

3

Reserved for system

-

-

4

Reserved for system

-

-

5

Reserved for system

-

-

6

Warning

One of the sensor amplifiers is in
warning state.

0: No warning
1: Warning

7

Error status

Stores the error status of the sensor
amplifiers.

"Types of error and error code"

(page 29)

0: No error occurred.
1: Error occurred.

1

0

External input response 1

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

1

External input response 2

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

2

External input response 3

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

3

External input response 4

Stores the external input response
to the sensor amplifier.

0: No input
1: Input reception

4

Reserved for system

-

-

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Reserved for system

-

-

2 to 15

0 to 7 Reserved for system

-

-

Address

Bit

Function name

Description

Value

16+7(a-1)*

0

High

ON/OFF of the High state of the
sensor amplifiers is output.

0: OFF
1: ON

1

Low

ON/OFF of the Low state of the
sensor amplifiers is output.

0: OFF
1: ON

2

Go

ON/OFF of the Go state of the
sensor amplifiers is output.

0: OFF
1: ON

3

Reserved for system

-

-

4

Reserved for system

-

-

5

Reserved for system

-

-

6

Reserved for system

-

-

7

Reserved for system

-

-