beautypg.com

Access address (slot 1 to 4) – KEYENCE DL-PN1 User Manual

Page 16

background image

14

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

*1 Functions assigned to the external input request 1 to 4 are as follows:

External input request 1: ZERO SHIFT input

External input request 2: RESET input

External input request 3: TIMING input

External input request 4: ADJUST input

Functions assigned to the external input request 1 to 4 can be changed.
Refer to the IB series user's manual.

*2 If the judgment value is correct, the parameter range is

- from - 999.97 to +999.98 (percent mode).
- from - 99.997 to +99.998 (size mode).
In percent mode:

When the comparator value is over range, "+999.99" is stored.

When the comparator value is under range, "-999.99" is stored.

When the comparator value is invalid, "-999.98" is stored.

When an error occurs, "+1000.00" is stored.

In size mode:

When the comparator value is over range, "+99.999" is stored.

When the comparator value is under range, "-99.999" is stored.

When the comparator value is invalid, "-99.998" is stored.

When an error occurs, "+100.000" is stored.

Access Address (Slot 1 to 4)

180 to

191

Reserved for system

192

Setting error

When the sensor amplifier
setting is abnormal, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

193

EEPROM writing

When the sensor amplifier is
reflecting the setting after the
setting change, the
corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

194

Laser emission stop status

When the light emission of
the sensor amplifier stops,
the corresponding bit is set.

2byte

WORD

R

bit0

: Reserved for system

bit1

: Slot 1
:

bit15 : Slot 15

Index

(DEC)

Function name

Description

Data

type

Attribute

Value

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

0

Reserved for system

1

Zero shift request

DINT

C

2

Zero shift reset request

DINT

C

3

Reset request

DINT

C

4

Error clear request

DINT

C

5

Initial reset request

DINT

C

6

System parameter set request

DINT

C

7 to 9

Reserved for system