Access address (slot 0) – KEYENCE DL-PN1 User Manual
Page 13
11
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
Point
To input the ID number for the DL-PN1 into ID, refer to the instruction
manual for each PLC. When inputting the ID number of the sensor
amplifier connected to the DL-PN1 into ID, input the smaller of the Slot
I Address and Q Address. If Q Address will be input, add
32768(0x8000).
Access Address (Slot 0)
RECORD
A value is input when reading. Inputs a value when writing.
VALID
Replies as to whether the action was valid.
BUSY
Replies as to whether the unit is busy.
ERROR
Replies as to whether there is an error.
STATUS
Replies with status information (including error information).
LEN
Replies the length of the reply data.
Parameter name
Description
Index
(DEC)
Function name
Description
Data
type
Attribute
Value
0
Key lock
The sensor amplifier enters
the key lock state.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
1
Key unlock
The key lock of the sensor
amplifier is canceled.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
2
Power saving function
(ECO)
The sensor amplifier enters
the eco mode.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
3
Power saving function
(ECO) cancel
The eco mode of the sensor
amplifier is canceled.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
4
Light emission stop
request
Light emission of the sensor
amplifier is stopped.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
5
Light emission stop cancel
Light emission stop of the
sensor amplifier is canceled.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
6 to 14
Reserved for system
15
Initialization request
Initializes the sensor
amplifier.
2byte
WORD
W
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
16 to 31 Reserved for system
32
DL-PN1 error state
Stores the DL-PN1 error
status.
2byte
WORD
R
33
Number of connectable
units
Stores the number of sensor
amplifiers connected to the
DL-PN1.
2byte
INT
R
0 to 15
34 to 63 Reserved for system