Reading comparator values (P.V. values) from sensor amplifiers
This example shows how to read the comparator values (P.V.values) from the sensor
amplifiers ID01, ID02, and ID03.
(1) When the comparator value of a sensor amplifier is updated, the value of the input
address is also updated via data I/O communication.
If the judgment value is correct, the parameter range is
- from - 999.99 to +999.99 (percent mode).
- from - 99.999 to +99.999 (size mode).
If the comparator value is over range, under range, or invalid, the previous value is
retained without updating the comparator value. To confirm whether the current
value is correct, use the comparator value property.
(2) The comparator value invalid, comparator value over range, or comparator value
under range is entered.
If the comparator value of a sensor amplifier is "invalid", "over", or "under", the bit
corresponding to the ID number of that sensor amplifier flips to 1.
(1)
Master
Comparator value under range
Input address 17/24/31 Bit 3 of Slot 1/2/3
Comparator value of ID 01
1234
4567
6789
Input address 19 to 22 (DEX) of Slot 1
Comparator value of ID 02
2345
5678
7890
Input address 26 to 29 (DEX) of Slot 2
Comparator value of ID 03
3456
8901
Input address 33 to 36 (DEX) of Slot 3
Sensor amplifier
Comparator value of ID 01
1234
4567
6789
Comparator value of ID 02
2345
5678
7890
Comparator value of ID 03
3456
8901
Comparator value over range
Input address 17/24/31 Bit 2 of Slot 1/2/3
Comparator value invalid
Input address 17/24/31 Bit 1 of Slot 1/2/3