KEYENCE DL-PN1 User Manual
Page 22
20
- PROFINET Communication Unit DL-PN1 User's Manual (IB) -
*1 The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to the
IB Series User's Manual.
*2 Details of output status can be checked by noting the ON/OFF state of each bit.
167
Error output mode
DINT
R/W
0
0: Normal mode (Default)
1: LX2 compatible mode
168
Hysteresis for trigger level
DINT
R/W
0
0: Default
1: User setting
169
Hysteresis set value for
trigger level
*16
DINT
R/W
1.00
0.00 to 999.99
170 to
191
Reserved for system
192
Group6 Entry count
DINT
R
11
193
Product code
DINT
R
Main unit:=4020
Expansion unit:=4021
194
Reserved for system
195
Transmitter head model
DINT
R
0: Sensor head is not connected,
or light receiver is connected.
1: Light transmitter of IB-01 is
connected.
2: Light transmitter of IB-05 is
connected.
3: Light transmitter of IB-10 is
connected.
4: Light transmitter of IB-30 is
connected.
196
Receiver head model
DINT
R
0: Sensor head is not connected,
or light transmitter is connected.
1: Light receiver of IB-01 is
connected.
2: Light receiver of IB-05 is
connected.
3: Light receiver of IB-10 is
connected.
4: Light receiver of IB-30 is
connected.
197 to
199
Reserved for system
200
Product name 1
*20
DINT/
STRING
R
Main unit:="IB-1"
Expansion unit:="IB-1"
201
Product name 2
*20
DINT/
STRING
R
Main unit:="000/"
Expansion unit:="050/"
202
Product name 3
*20
DINT/
STRING
R
Main unit:="1500"
Expansion unit:="1550"
203
Product name 4
*20
DINT/
STRING
R
Main unit:=""
Expansion unit:=""
204 to
217
Reserved for system
218
Unit
219 to
223
Reserved for system
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value