*13 This command reads the execution result of the "tolerance tuning request", "2-point

tuning HIGH side 2nd request", or "2-point tuning LOW side 2nd request" motion
command whichever was last issued.

*14 This parameter works if "Bank switching method" is set to "button."
*15 These parameters are OFF only if data "0" is written and the wiring is configured to

turn off external input.

*16 When reading data from an amplifier unit in which the measurement mode is to

"dimension mode", the read range changes to "**.***" (0.000 to 99.999).

*17 A write control error results if data is rewritten to an expansion unit.
*18 To have the sensor amplifier reflect the settings written in data numbers 146 to 149,

it is necessary to set data number 145 to "1" (user setting), or to set the external
input to "user setting" via button operation on the sensor amplifier.

*19 An attempt to write this data results in an error. (Reading is results in "0.")
*20 The read value of the two-digit value can be translated to a binary number, so that

the ON/OFF state of each bit can be noted to know the status of judgment output
and check output.

Assume the read data is "05":
Translating "05" to a binary number gives "0101".
N.O. mode

*21 The external input status is "1" when the external input is ON, and is "0" when the

external input is OFF. Bits 0, 1, 2, and 3 correspond to external inputs 1, 2, 3, and 4,
respectively.

Assume the read data is "06":
Translating "6" to a binary number gives "0110".

*22 The result of "measured correction" and "logical correction" can be checked. This

data is not available if "calibration function" is set to "no correction."

Bit

Judgment output

N.O. mode

N.C. mode

0

0: HIGH judgment output OFF
1: HIGH judgment output ON

0: HIGH judgment output ON
1: HIGH judgment output OFF

1

0: LOW judgment output OFF
1: LOW judgment output ON

0: LOW judgment output ON
1: LOW judgment output OFF

2

0: GO judgment output OFF
1: GO judgment output ON

0: GO judgment output ON
1: GO judgment output OFF

3

0: Check output OFF
1: Check output ON

0: Check output ON
1: Check output OFF

Reference

0 1 0 1

Bit 3: Alarm output OFF

Bit 2: GO judgment output ON

Bit 0: HIGH judgment output ON
Bit 1: LOW judgment output OFF

Reference

0 1 1 0

External input 4: OFF

External input 3: ON

External input 1: OFF
External input 2: ON