beautypg.com

KEYENCE DL-PN1 User Manual

Page 19

background image

17

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -

64

Group2 Entry count

DINT

R

12

65

HIGH setting value (BANK 0)

*7

DINT

R/W

+20.00

-999.99 to +999.99

66

LOW setting value (BANK 0)

*7

DINT

R/W

+10.00

-999.99 to +999.99

67

Shift target value (BANK 0)

*7

DINT

R/W

0.00

-999.99 to +999.99

68

HIGH setting value (BANK 1)

*7

DINT

R/W

+20.00

-999.99 to +999.99

69

LOW setting value (BANK 1)

*7

DINT

R/W

+10.00

-999.99 to +999.99

70

Shift target value (BANK 1)

*7

DINT

R/W

0.00

-999.99 to +999.99

71

HIGH setting value (BANK 2)

*7

DINT

R/W

+20.00

-999.99 to +999.99

72

LOW setting value (BANK 2)

*7

DINT

R/W

+10.00

-999.99 to +999.99

73

Shift target value (BANK 2)

*7

DINT

R/W

0.00

-999.99 to +999.99

74

HIGH setting value (BANK 3)

*7

DINT

R/W

+20.00

-999.99 to +999.99

75

LOW setting value (BANK 3)

*7

DINT

R/W

+10.00

-999.99 to +999.99

76

Shift target value (BANK 3)

*7

DINT

R/W

0.00

-999.99 to +999.99

77 to 95 Reserved for system

96

Group3 Entry Count

DINT

R

20

97

Key lock setting

DINT

R/W

0

0: Release
1: Key lock

98

Bank setting

*14

DINT

R/W

0

0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3

99

Timing input

*15

DINT

R/W

0

0: Timing input OFF
1: Timing input ON

100

Laser emission stop input

*15

DINT

R/W

0

0: Emission stop input OFF
1: Emission stop input ON

101 to

103

Reserved for system

104

Sub display's screen

DINT

R/W

0

0: R.V. value screen
1: Analog value screen
2: HIGH setting value screen
3: LOW setting value screen
4: Shift target value setting

screen

105

System parameter

*12

DINT

R/W

0

Main unit: 0 to 9
Expansion unit: 0 to 1

106

Tolerance tuning setting width

*16

DINT

R/W

10.00

0.00 to 999.99

107

Calibration function

DINT

R/W

0

0: No correction (Default)
1: Measured correction
2: Logical correction

108

Measured/Logical correction
target 1

*7

DINT

R/W

0.00

-999.99 to +999.99

109

Measured/Logical correction
target 2

*7

DINT

R/W

+100.00

-999.99 to +999.99

110 to

114

Reserved for system

115

Logical correction measured 1

*7

DINT

R/W

0.00

-999.99 to +999.99

116

Logical correction measured 2

*7

DINT

R/W

+100.00

-999.99 to +999.99

117 to

127

Reserved for system

128

Group4 Entry count

DINT

R

30

129

Reserved for system

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value