GLOBAL MENU

57

CALIBRATION
The Analog Rytm calibration routine is found here.

CALIBRATION will start the calibration routine for the oscillators and filters. After selecting this option, a popup
window asking to confirm the calibration will appear. Press [YES/SAVE] to proceed with the calibration. Please
note that the calibration routine takes a while to complete.

Analog Rytm is factory calibrated. It should not be re-calibrated unless specifically stated by Elek-
tron Support.

Before calibrating, it is important that the unit has been turned on for at least two hours in order to attain
working temperature.

OS UPGRADE
This menu option is used when upgrading Analog Rytm OS. To send the OS syx file, use our free SysEx utility
software C6. The OS syx file and the C6 software can be downloaded from the Elektron website.

Press [YES/SAVE] to make Analog Rytm start listening for incoming OS SysEx data.

If you wish to cancel the waiting state, press [NO/RELOAD].

For the transfer to be possible, the device sending the OS syx-file must be connected to either the MIDI IN or
USB port of Analog Rytm.

Please note that the Analog Rytm will not appear as an icon on your computer desktop.

On your computer, download the OS syx file, open the C6 software. Click “configure” and select Elektron Analog
Rytm for MIDI In as well as MIDI Out. Drag the syx file to the C6 main window, then highlight it by pointing and
clicking on it with the mouse pointer. Point and click on the “send” button in the top left corner of the C6 window.

When receiving the OS, a progress bar will be visible on the Analog Rytm LCD screen. Once the bar has been
filled, the message “ERASING FLASH” will be shown on the screen, shortly followed by the message “WRITING
FLASH”. This takes a short while. When this process is successfully completed, the OS is updated and the unit
reboots.