beautypg.com

Installation guidelines – Waterworks Highgate Volume Control Valve Trim with White Porcelain Lever Handle User Manual

Page 2

background image


HIGHGATE

Volume Control Valve Trim

INSTALLATION GUIDELINES

Page 2 of 3

6.6.2012

These guidelines have been prepared for the professional contractor to aid in the installation of:
HIGHGATE VOLUME CONTROL VALVE TRIM WITH METAL CROSS HANDLE (STYLE# HGVC40) &
PORCELAIN LEVER HANDLE (STYLE# HGVC50)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

Figure - 02
(Shown with GUSV18R)

3

1

4

"MIN

4

1

4

"MAX

ROUGH-IN

Cartridge Stem*

Finished Wall

CUT STEM 1

3

8

"

FROM FINISHED

WALL

4. Re-install the threaded tube onto the valve.

5. Hold the escutcheon (3) to the finished wall then

thread the handle gland cover onto the threaded
tube to hold the escutcheon against the finished
wall. Make sure the washer (4) is behind the
escutcheon.

TRIM INSTALLATION WITH DIVERTER VALVE:

6. Remove the tile guard and make a mark on the tube

that is 5/8" from the surface of the finished wall.

7. Remove the tube then cut the tube at the mark

made in Step 6. DO NOT cut the end of the tube
with the internal threads. See Figure-03.

8. Mark then cut the cartridge stem 1-1/2" from the

surface of the finished wall. See Figure-04.

9. Re-install the threaded tube onto the valve.

10. Hold the diverter plate† (SOLD SEPARATELY) and

escutcheon (3) to the finished wall then thread the
handle gland cover (1 or 2) onto the threaded tube
to hold the escutcheon and plate against the
finished wall. Make sure the washer (4) is behind the
escutcheon.

¾

If further assistance is required, please contact

Product Support at 1-800-927-2120 (9am-6pm EST).

Figure - 03
(Shown with GUSV14R)

Finished Wall

Threaded Tube*

3

1

4

"MIN

4

1

4

"MAX

ROUGH-IN

CUT TUBE

5

8

"

FROM FINISHED

WALL

Figure - 04
(Shown with GUSV14R)

Finished Wall

Cartridge Stem*

3

1

4

"MIN

4

1

4

"MAX

ROUGH-IN

CUT STEM 1

1

2

"

FROM FINISHED

WALL

*

If required, a 1" stem extension is available.

Style No. 890831

Item

No.

29-72873-53591

GUSV14R requires the 2-Way Thermostatic Diverter
Valve Trim (Plate Only): Style No. UNDV00


GUSV23R

requires the 2-Way Pressure Balance

Diverter Valve Trim (Plate Only): Style No. UNDV10