28.Using the limit stop button as a pointer, align it to
the corresponding temperature reading obtained in
step 26 on the trim plate (6) then press this
assembly against the trim nut.
29.Tighten all of the set screws.
30.Turn on the water and take a reading of the water
temperature. Confirm that the temperature
readings correspond to the digits on the
escutcheon plate and if they do not, repeat the
calibration procedures.
31.Slide the cover (3b) onto the limit stop assembly
and attach the handle.
32.Confirm the safety limit is functioning properly by
turning the handle counter-clockwise at which
point it should stop with the limit stop button
pointing to approximately 100 degrees. Bypass the
limit stop by pressing the limit stop button and
rotating the handle. It is NOT recommended to
exceed the safety limit stop of 100 degrees.
33.Temperature settings should be checked
periodically to ensure that proper calibration is
maintained.
If further assistance is required, please contact Product
Support at 1-800-927-2120 (8am-7pm EST).
W A T E R W O R K S
Waterworks is a registered trademark of Waterworks Inc.
These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA THERMOSTATIC SHOWER VALVE TRIM WITH CROSS HANDLE (JUSV59-K)
& LEVER HANDLE (JUSV60-K, JUSV61-K, JUSV62-K) All dimensions are based on original
specification and are subject to change and variation. Please consult your Design Associate for current
specifications.
Julia Thermostatic Shower Valve Trim
10.06.06