Installation Guidelines

28.Using the limit stop button as a pointer, align it to

the corresponding temperature reading obtained in

step 26 on the trim plate (6) then press this
assembly against the trim nut.

29.Tighten all of the set screws.

30.Turn on the water and take a reading of the water

temperature. Confirm that the temperature

readings correspond to the digits on the
escutcheon plate and if they do not, repeat the
calibration procedures.

31.Slide the cover (3b) onto the limit stop assembly

and attach the handle.

32.Confirm the safety limit is functioning properly by

turning the handle counter-clockwise at which

point it should stop with the limit stop button
pointing to approximately 100 degrees. Bypass the

limit stop by pressing the limit stop button and
rotating the handle. It is NOT recommended to

exceed the safety limit stop of 100 degrees.

33.Temperature settings should be checked

periodically to ensure that proper calibration is
maintained.

If further assistance is required, please contact Product

Support at 1-800-927-2120 (8am-7pm EST).

W A T E R W O R K S

Waterworks is a registered trademark of Waterworks Inc.

These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA THERMOSTATIC SHOWER VALVE TRIM WITH CROSS HANDLE (JUSV59-K)

& LEVER HANDLE (JUSV60-K, JUSV61-K, JUSV62-K) All dimensions are based on original
specification and are subject to change and variation. Please consult your Design Associate for current
specifications.

Julia Thermostatic Shower Valve Trim

10.06.06