Waterworks Julia Thermostatic Control Valve Trim with White Porcelain Lever Handles User Manual
Installation guidelines, Julia thermostatic shower valve trim
Installation Guidelines
W A T E R W O R K S
Waterworks is a registered trademark of Waterworks Inc.
10.06.06
These guidelines have been prepared for the professional contractor to aid in the installation of:
JULIA THERMOSTATIC SHOWER VALVE TRIM WITH CROSS HANDLE (JUSV59-K)
& LEVER HANDLE (JUSV60-K, JUSV61-K, JUSV62-K) All dimensions are based on original
specification and are subject to change and variation. Please consult your Design Associate for current
specifications.
5
7
8
"Ø
3
5
8
"
FIGURE 1
12
11
10
7
12a
9 x2
8
7a
IMPORTANT
To ensure this product is installed properly, you
must read and follow these guidelines.
The owner/user of the valve must keep this
information for future reference.
This valve includes integrated service stops.
Make sure the tile guard is in place.
This valve features anti scald protection. The risk
of scalding exists until the installer has properly
calibrated/adjusted the temperature setting
during final trim installation.
Valve body rough-in depth is 2
1
2
" when measured
from the centerline of the inlets to the surface of
the finished wall.
Be sure your installation conforms to local codes.
This thermostatic valve only mixes hot and cold
water and does not have volume control or shut
off capability. A diverter or wall valve (provided
separately) control on/off/volume and must be
installed for each fitting that will have water flowing
to it.
This product must be installed by a professional
contractor.
Refer to the specification and assembly drawings
attached. Shower valve trim and valve are sold
partially assembled but shown fully disassembled
for illustrative and service purposes only.
If soldering any connections, remove cartridge to
prevent damage to seals and internal assembly.
This shower valve trim should be on-site prior to
rough in and allows the installer to visualize the
installation.
Inspect this product to assure you have all parts
shown that are required for proper installation.
Check incoming water pressure; ideal operating
pressure is 50-60 psi. The minimum is 25 psi and
the maximum is 80 psi.
ROUGH IN:
1. Make sure the valve body (12,12a) is positioned
according to valve markings so the inlets are
situated with hot piped on the left and cold piped
on the right. Positioned correctly, notice the inlets
are below an imaginary horizontal line drawn
between the 2 cover screws (9).
IMPORTANT: Valve rough-in depth is 2
1
2
"
when measured from the centerline of the inlets to
the surface of the finished wall.
2. Run
3
4
" copper supply lines to the proper height of
the valve inlets and be sure to secure all piping and
fittings.
3. For each shower fitting that will have water flowing
to it, install a wall valve or diverter valve (both
provided separately) at the same rough-in depth
and according to the flow direction arrow marked
on the wall valve or diverter valve body.
3
1
2
"
Julia Thermostatic Shower Valve Trim
JUSV59-K (cross handle)
JUSV60-K (metal lever handle)
JUSV61-K (white porcelain lever handle)
JUSV62-K (black porcelain lever handle-MTO)
JUSV60-K
JUSV61-K, 62-K
3
3
8
"
2
1
2
"