Waterworks Formwork Thermostatic Control Valve Trim with Metal Knob Handle User Manual
Installation guidelines

PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
FORMWORK
Thermostatic Control Valve Trim with Metal Knob Handle
Installation Guidelines
Page 1 of 3
Rev - 01
4.8.2014
These guidelines have been prepared for the professional contractor to aid in the installation of:
FORMWORK THERMOSTATIC CONTROL VALVE TRIM WITH METAL KNOB HANDLE (STYLE No. FMTH01)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
STYLE No. FMTH01
SPECIFICATIONS:
Control Valve Rough-in Depth Min: 3-1/8"
Control Valve Rough-in Depth Max: 4-3/4"
Fittings Hole Diameter: Ø5-1/4"
Hot Limit Safety Stop: Yes
REQUIRED PLUMBING DETAILS:
Universal 3/4" Thermostatic Valve
STYLE No. GUTH37
IMPORTANT:
¾ To ensure this product is installed properly, you must
read and follow these guidelines.
¾ The owner/user of this product must keep this
information for future reference.
¾ This product must be on-site prior to rough-in. This
allows the installer to visualize the installation and
verify the center spread.
¾ This product must be installed by a professional
licensed contractor.
¾ Inspect the product to ensure you have all the parts
required for proper installation.
¾ Be sure your installation conforms to all federal, state,
and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.
¾ This product is intended to work with the Universal
3/4" Thermostatic Valve (Style No. GUTH37 - SOLD
SEPARATELY) which features anti-scald protection.
The risk of scalding exists until the installer has
properly calibrated/adjusted the temperature setting
during final trim installation.
¾ The Universal 3/4" Thermostatic Valve (Style No.
GUTH37) only mixes hot and cold water. It does not
have volume or shut-off capabilities. A diverter or wall
valve (SOLD SEPARATELY) control on/off/volume
and must be installed for each fitting that will have
water flowing to it.
¾ Refer to the specification and assembly drawings
attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.
¾ Use only a strap wrench or protected/smooth-jaw
wrench on any finished surface.
¾ DO NOT use putty. Putty contains oil and can cause
permanent discoloration on certain materials such as
marble, granite and any porous surface.
TRIM INSTALLATION:
1. Remove the TILE GUARD from the VALVE.
¾ See Figure - 01 for steps 2 & 3
FIGURE - 01
2. Thread the ALL THREAD TUBE onto the VALVE until
it seats then slide the TRIM PLATE over the ALL
THREAD TUBE as shown in Figure - 01.
3. While holding the TRIM PLATE against the finished
wall, mark the ALL THREAD TUBE at a point 3/16"
beyond where it protrudes from the TRIM PLATE as
shown in Figure - 01.
TRIM PLATE
FINISHED WALL
LIMIT STOP PIN
ALL THREAD TUBE
CENTER
OF INLET
VALVE
3/16"
CUT ALL THREAD TUBE
ROUGH-IN DEPTH
TRIM PLATE
FINISHED WALL
LIMIT STOP PIN
ALL THREAD TUBE
CENTER
OF INLET
VALVE