Waterworks Easton Vintage Volume Control Valve Trim with Oak Lever Handles User Manual
Installation guidelines
➢ Inspect this product to assure you have all parts required for
proper installation.
➢ Use only a strap wrench or protected/smooth-jaw wrench
on any finished surface.
ROUGH IN:
➢ REQUIRED: Ideal valve body rough-in depth is 2
1
/
2
" from the
centerline of the inlets to the face of the finished wall.
1. Remove the tile shield (4) and unthread the threaded sleeve
(3) from the valve body.
2. If soldering any connections, remove the cartridge to prevent
damage to seals.
3. For each fitting that will have water flowing to it, install a wall
valve according to the flow direction arrow marked on the
side of the wall valve body.
4. Run
3
/
4
" copper supply lines to the proper height of the valve
inlets and be sure to secure all piping and fittings. Install the
valve at a height and spread (if applicable) that is
comfortable to the user.
5. Reinstall the cartridge and threaded sleeve, making sure the
tile shield is attached.
ATTACH THE TRIM:
➢ Before attaching the trim, verify the rough-in depth from the
centerline of the inlets to the face of the finished wall is 2
1
/
2
".
- If the rough in depth is between 2
1
/
2
" and 2
3
/
4
", proceed
to step 18.
- If the rough in depth is more than 2
3
/
4
", proceed to step 6.
6. Pull the tile shield (4) off the threaded sleeve (3) and then
thread the handle trim connector assembly (6-10) onto the
threaded sleeve until it stops.
7. Slide the esctcheon (5) onto the handle trim connector
assembly and then thread on the handle (14-17).
8. Slide the escutcheon (5) back until it contacts the nut (14).
9. Measure the distance from the face of the finished wall to
the back side of the escutcheon.This measurement will be
the length of threaded sleeve that will be cut off in step 11.
10.Remove the handle assembly, handle trim connector (6-10),
and threaded sleeve.
11.Mark and then cut the threaded sleeve the amount equal
to what was measured in step 8. Do NOT cut the end of
the threaded sleeve that has internal threads or handle trim
Easton
®
Wall Valve Trim - Uncovered & Covered
These guidelines have been prepared for the professional contractor to aid in the installation of:
EASTON
®
WALL VALVE TRIM (UNCOVERED-EASV11,12-K,13-K14-K,15-
K)(COVERED-EASV01,02-K,03-K,04-K,05-K)
All dimensions are based on original specifications and are subject to change and variation.
Please consult your Design Associate for current specifications.
Installation Guidelines
1
W A T E R W O R K S
®
12/03
UNCOVERED
EASV11(CROSS HANDLE)
EASV12-K(ALL METAL LEVER HANDLE)
EASV13-K(WHITE PORCELAIN LEVER HANDLE)
EASV14-K(BLACK PORCELAIN LEVER HANDLE)
EASV15-K(OAK LEVER HANDLE)
3"
3"
3
1
/
2
"
3
1
/
8
"
2
1
/
2
"
2
3
/
4
"
3"
2
1
/
2
"
2
3
/
4
"
3"
3"
3
1
/
2
"
3"
3
1
/
8
"
Notes:
• 2
1
/
2
" rough in depth
•
3
/
4
" female NPT inlets
INSTALLATION GUIDELINES:
IMPORTANT:
➢
➢ T
To
o e
en
nssu
urre
e tth
hiiss p
prro
od
du
ucctt iiss iin
nssttaalllle
ed
d p
prro
op
pe
errllyy,, yyo
ou
u m
mu
usstt rre
eaad
d aan
nd
d
ffo
ollllo
ow
w tth
he
esse
e ggu
uiid
de
elliin
ne
ess..
➢
➢ T
Th
he
e o
ow
wn
ne
err//u
usse
err o
off tth
hiiss vvaallvve
e m
mu
usstt kke
ee
ep
p tth
hiiss iin
nffo
orrm
maattiio
on
n ffo
orr
ffu
uttu
urre
e rre
effe
erre
en
ncce
e..
➢ Valve body rough-in depth is 2
1
/
2
" from the centerline of the
inlets to the face of the finished wall.
➢ Be sure your installation conforms to federal, state, and local
codes.
➢ Wall valves control on/off/volume and must be installed for each
fitting that will have water flowing to it. If using a wall valve with
our thermostatic valve, refer to the Installation Guidelines
for the Thermostatic Valve which contains related installation
information.
➢ This product must be installed by a professional contractor.
➢ Refer to the specification and assembly drawings attached.Valves
are sold partially assembled but shown fully disassembled for
illustrative and service purposes only.
➢ This valve should be on-site prior to rough-in and allows the
installer to visualize the installation.
COVERED
EASV01(CROSS HANDLE)
EASV02-K(ALL METAL LEVER HANDLE)
EASV03-K(WHITE PORCELAIN LEVER HANDLE)
EASV04-K(BLACK PORCELAIN LEVER HANDLE)
EASV05-K(OAK LEVER HANDLE)