beautypg.com

Pilz PNOZ s4 C 48-240VACDC 3 n/o 1 n/c User Manual

Page 18

background image

PNOZ s4

Operating Manual PNOZ s4
21396­EN­13

18

Times

750104

750134

751104

Switch­on delay

With automatic start
typ.

170 ms

170 ms

170 ms

With automatic start
max.

300 ms

300 ms

300 ms

With automatic start
after power on typ.

350 ms

350 ms

350 ms

With automatic start
after power on max.

600 ms

600 ms

600 ms

With manual start typ.

40 ms

40 ms

40 ms

With monitored start
with rising edge typ.

35 ms

35 ms

35 ms

With monitored start
with rising edge max.

50 ms

50 ms

50 ms

With monitored start
with falling edge typ.

55 ms

55 ms

55 ms

With monitored start
with falling edge max.

70 ms

70 ms

70 ms

Delay­on de­energisation

With E­STOP typ.

10 ms

10 ms

10 ms

With E­STOP max.

20 ms

20 ms

20 ms

With power failure typ. 40 ms

40 ms

With power failure max. 80 ms

80 ms

With power failure typ.
UB 240 V

300 ms

With power failure max.
UB 240 V

450 ms

Recovery time at max.
switching frequency 1/s

After E­STOP

100 ms

50 ms

100 ms

After power failure

100 ms

100 ms

100 ms

Waiting period with a
monitored start

With rising edge

120 ms

120 ms

120 ms

With falling edge

250 ms

150 ms

250 ms

Min. start pulse duration
with a monitored start

With rising edge

30 ms

30 ms

30 ms

With falling edge

100 ms

100 ms

100 ms

Supply interruption before
de­energisation

20 ms

20 ms

20 ms

Simultaneity, channel 1
and 2

Environmental data

750104

750134

751104

Climatic suitability

EN 60068­2­78

EN 60068­2­78

EN 60068­2­78

Ambient temperature

Temperature range

­10 ­ 55 °C

­10 ­ 55 °C

­10 ­ 55 °C