Pilz PNOZ s4 C 48-240VACDC 3 n/o 1 n/c User Manual
Page 10

PNOZ s4
Operating Manual PNOZ s4
21396EN13
10
Light beam device or safety
switch with detection of
shorts across contacts via
ESPE
(only when U
B
= 24 VDC)
S12
S22
24 V DC
A2
GND
NOTICE
When used as a safety component in accordance with EN 811:
– The switch that is used must be designed as a safety switch in ac
cordance with 14.1.2.2 of EN 811, so that a failure to open when en
ergised is excluded.
– The supply lines to the safety switch must be laid in accordance with
13.5 of EN 811 so that short circuits that would bridge the contacts
in the switch can be excluded.
}
Reset circuit/feedback loop
Reset circuit/feedback loop
Reset circuit
Feedback loop
Automatic reset
K5
K6
K5
L1
N
K6
S12
13 (23,33)
S34
14 (24,34)
Manual/monitored reset
S12
S34
S3
K5
K6
K5
L1
K6
S12
S34
S3
N
13 (23,33)
14 (24,34)
}
Semiconductor output
U
B
24 VDC
U
B
48 240 VAC/DC
*Connect together the 0V connections on all
the external power supplies
Legend
}
S1/S2: ESTOP/safety gate switch
}
S3: Start button
}
: Switch operated
}
: Gate open
}
: Gate closed