beautypg.com

Casio SERIES FX-9860G User Manual

Page 185

background image

20070201

5-2-2

Controlling What Appears on a Graph Screen

u V-Window Setting Precautions

• Inputting zero for T

θ ptch causes an error.

• Any illegal input (out of range value, negative sign without a value, etc.) causes an

error.

• When T

θ max is less than T θ min, T θ ptch becomes negative.

• You can input expressions (such as 2

π) as V-Window parameters.

• When the V-Window setting produces an axis that does not fi t on the display, the scale

of the axis is indicated on the edge of the display closest to the origin.

• Changing the V-Window settings clears the graph currently on the display and

replaces it with the new axes only.

• Changing the Xmin or Xmax value causes the Xdot value to be adjusted automatically.

Changing the Xdot value causes the Xmax value to be adjusted automatically.

• A polar coordinate (

r

=) or parametric graph will appear coarse if the settings

you make in the V-Window cause the T

θ ptch value to be too large, relative to the

differential between the T

θ min and T θ max settings. If the settings you make cause

the T

θ ptch value to be too small relative to the differential between the T θ min and T θ

max settings, on the other hand, the graph will take a very long time to draw.

• The following is the input range for V-Window parameters.

–9.999999999

E

97 to 9.999999999

E

97