Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual
Page 65

Counterpart User Manual - Print Formatting
59
Command
Description
Supported Ticket
Formats
Gross weight in displayed units
GFMT
,
NFMT
,
TOTALFMT, PALFMT,
CFMT, ACCFMT
HDRFMT1, HDRFMT2
Net weight in displayed units
Tare weight in displayed units. Add four before bracket to print header
Accumulated weight in displayed units
Number of accumulator events (5-digit counter)
Date of last accumulator event
Time of last accumulator event
Unit ID number
Consecutive number
Piece count, current scale
Piece count, scale n
New line (nn = number of termination (
Space (nn = number of spaces)*
Suppress Units. Toggle weight data format (formatted/unformatted)**
Time
Date
Time & Date
Header 1
Header 2
Loaded ID Code - 32 characters maximum
Loaded ID Description - 32 characters maximum
Loaded ID Location - 12 characters maximum
Loaded ID Part Number - 32 characters maximum
Loaded ID Lot - 32 characters maximum
Loaded ID Units - 1 character maximum
Loaded ID Tare - 9 characters maximum (range 0.0 to 9999999.0)
Loaded ID Unit Weight - 9 characters maximum (range 0.0 to 9999999.0)
Loaded ID Quantity - 11 characters maximum (range -2000000000 to 2000000000)
Piece Count, current scale - 7 characters maximum (no explicit maximum value)
Piece Count, Scale n
Totalization Value - 11 character maximum (range -2000000000 to 2000000000)
Totalization Count - 4 characters maximum
Transaction Type - gives a “1” for receiving (in) or “0” for (sending out)
Note: This command cannot be used in any other format except Weighvault
Table 7-1. Print Format Commands