Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual
Page 61

Counterpart User Manual - Serial Commands
55
EDP.ECHO#p
Port echo
ON, OFF
EDP.EOLDLY#p
Port end-of-line delay
0–255 (0.1-second intervals)
EDP.HEADERS#p
Port header
ON, OFF
EDP.INPUT#p
Port input
CMD, SCANNER, SCALE, IND SC
EDP.PORT
Port reporting command. It responds to the port you are connected to.
EDP.RESPONSE#p
Port response
ON, OFF
EDP.SFMT#p
Port custom stream format
0-200 characters
EDP.SOURCE#p
Port source
1, 2, 3
EDP.STREAM#p
Port stream
OFF, LFT, INDUST
EDP.TERMIN#p
Port termination
CR/LF, CR
STR.POS
Custom stream identifiers
None, Space, +
None, Space, -
STR.NEG
STR.PRI
8 alphanumeric characters
STR.SEC
STR.TER
STR.GROSS
STR.NET
STR.TARE
STR.MOTION
2 alphanumeric characters
STR.RANGE
STR.OK
STR.INVALID
STR.ZERO
Command
Description
Values
CFGPWD
Configuration password
0, 1–9999999
CONSNUM
Consecutive numbering
0–9999999
CONSTUP
Consecutive number start-up value
0–9999999
DATEFMT
Date format
MMDDYYYY, DDMMYYYY, YYYYMMDD, YYYYDDMM
DATESEP
Date separator
SLASH, DASH, SEMI
DECFMT
Decimal format
DOT, COMMA
DSPBRIGHT
Sets display intensity
0 (dimmest), through 100 (brightest as a percentage)
KYBDLK
Keyboard lock (disable keypad)
OFF, ON
REG.AGENCY
Regulatory compliance
NONE, OIML, NTEP, CANADA, INDUST
REGULAT=NTEP
Regulatory compliance
NONE, OIML, NTEP, CANADA, INDUST
REG.CTARE
Allow clear keyed tare
NO, YES
REG.WORD
Weighing mode
Gross, Brutto
REG.KTARE
Always allow keyed tare
NO, YES
REG.MTARE
Multiple tare action
REPLACE, REMOVE, NOTHING
REG.NTARE
Allow negative tare
NO, YES
REG.ZTARE
Remove tare on ZERO
NO, YES
Table 6-8. FEATURE Serial Commands
Command
Description
Values
Table 6-7. SERIAL Port Serial Commands (Continued)