beautypg.com

Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 1.0 User Manual

Page 16

background image

10

Counterpart User Manual

Figure 2-3.

Counterpart CPU Board

If the RESET button on the CPU board is pressed, the scale will perform a reboot.

Jumper

Description

JP1/JP2
JP3/JP4

Jump excitation to sense. If using a 4-wire load cell cable, leave JP1 and JP2

on. If using a 6-wire load cell cable, take JP1 and JP2 off. Default is ON.

JP5/JP6

Used when upgrading firmware. The jumpers should be on when upgrading

firmware and off when the update is complete.

PC 1

JMP2

Power control. If the jumper is set to SW, the POWER key can be used to turn

the unit on/off. If set to ON, the unit will power on when plugged in and can only

be powered off by unplugging.

AUDIT

JMP1

If set to Audit ON, calibration and configuration can be accessed through the

front keypad. If set to Audit OFF, calibration and configuration can only be

accessed by removing the screws from the unit and pressing the Setup switch

with a screwdriver. Default is Audit ON.

Table 2-5. Jumper Descriptions

LED

LED

JP1 JP2

JP3 JP4

JP5 JP6

PC1 Jumper

P o w e r
Supply

D i s p l a y
Backlight

E t h e r n e t
Connector

D i s p l a y
connector

R S - 2 3 2
Connectors

Note